November 25, 2026
Europe/Bratislava timezone

Comparison of Direct and Indirect Treatment of Pollutants Using Dielectric Barrier Discharges

Not scheduled
1m
Vestibul pavilónu Fyziky

Vestibul pavilónu Fyziky

Zamestnanci Fyzika Poster session + coffee: works of research groups of the faculty Physics Poster session + káva: prezentácie vedeckých výsledkov FMFI UK - Fyzika

Speaker

Dr Kiran Ahlawat (Fakulta matematiky, fyziky a informatiky (Univerzita Komenského v Bratislave))

Description

Non-thermal atmospheric pressure plasma has gained considerable attention as an advanced oxidation technology for water treatment due to its ability to generate reactive oxygen and nitrogen species (RONS) for the degradation of organic pollutants [1]. The efficiency of plasma-based treatment depends on the plasma–liquid interaction, reactive species generation, and mass transfer into the aqueous phase[2,3]. This study investigates pollutant degradation using direct and indirect dielectric barrier discharge (DBD) plasma treatment configurations, with a particular focus on the influence of reactor configuration and gas–liquid interaction on degradation kinetics. A microbubble-enhanced cold plasma (MBECP) system was developed by integrating a DBD plasma source with a microbubble generator to enhance gas–liquid interfacial contact and facilitate the transfer of plasma-generated reactive species into water.
The MBECP system was operated using air and oxygen as feed gases, with an applied power of approximately 30–40 W and a discharge frequency of approximately 26 kHz. Methylene blue (MB, 10 mg L⁻¹) degradation was investigated in 550 mL of aqueous solution at different gas-flow rates ranging from 0.7 to 2.7 standard L min⁻¹. The air-fed MBECP system achieved complete MB decolorization within 1.5 min, with an energy yield of 7425 mg kWh⁻¹, demonstrating its potential for rapid pollutant degradation. The degradation kinetics exhibited a strong dependence on gas-flow rate, with higher flow rates resulting in faster degradation. At 2.7 SLPM, near-complete MB degradation was achieved within 2–3 min, whereas the lowest flow rate of 0.7 SLPM exhibited a pronounced degradation plateau. These observations indicate that reactive species production and delivery play a critical role in determining treatment efficiency. Bubble characterization further revealed a transition from relatively uniform bubbling to a denser, coalescence-dominated regime at higher gas-flow rates.
Reactive species analysis confirmed the generation of hydroxyl radicals (•OH) in both air- and oxygen-fed MBECP configurations, with enhanced radical production observed under oxygen feed conditions. Scavenger experiments using D-mannitol and L-histidine identified singlet oxygen (¹O₂) as the dominant oxidant responsible for MB degradation, with •OH contributing as a secondary oxidizing species. The comparative investigation of direct and indirect plasma treatment further revealed the influence of plasma configuration on pollutant degradation. In particular, coumarin degradation proceeded faster in the second stage of the dual-stage DBD system than in the single-stage MBDBD configuration, indicating improved degradation kinetics with the two-stage treatment arrangement.
Overall, the findings highlight the importance of plasma configuration, gas-flow conditions, reactive species generation, and gas–liquid mass transfer in determining pollutant degradation efficiency. The comparative study provides valuable insights into the optimization of DBD-based plasma systems for advanced water treatment applications.
References
1. Abdulsalam, M., Kimani, B. G., Ahlawat, K. & Machala, Z. Emerging contaminants in water pathways: sources, impacts, conventional, and cold-plasma-based cleaner technology assessment. Environmental Science and Pollution Research 2026 33:34 33, 16747–16778 (2026).
2. Abdulsalam, M. et al. Enhanced plasma-photocatalysis degradation of coumarin using modified fountain dielectric barrier discharge and WO₃/ZnO nanoparticles. Journal of Water Process Engineering 86, 109893 (2026).
3. Ahlawat, K., Chithran, A., Kimani, B. G. & Machala, Z. Decoupling nitrogen fixation from degradation: A dual-function DBD plasma-bubble system for sustainable wastewater treatment. Journal of Water Process Engineering 91, 110553 (2026).

Pracovisko fakulty (katedra)/ Department of Faculty Division of Environmental Physics Department of Astronomy, Earth Physics and Meteorology Faculty of Mathematics, Physics and Informatics Comenius University Bratislava
Tlač postru/ Print poster Budem požadovať tlač /I hereby required to print the poster in faculty

Author

Dr Kiran Ahlawat (Fakulta matematiky, fyziky a informatiky (Univerzita Komenského v Bratislave))

Co-author

Zdenko Machala (Division of Environmental Physics, Faculty of Mathematics, Physics and Informatics, Comenius University)

Presentation materials

There are no materials yet.