November 25, 2026
Europe/Bratislava timezone

Design and Development of High-Voltage Electronics and a DC-Excited 10.6 eV Krypton Vacuum Ultraviolet Lamp for Photoionization Ion Mobility Spectrometry in the Study of BTX in Indoor Air

Not scheduled
1m
Študenti Fyzika Poster session + coffee: works of students of the faculty Physics Poster session + káva: prezentácie študentov - Fyzika

Speaker

Mr Ashish Kumar (Katedra experimentálnej fyziky, Fakulta matematiky, fyziky a informatiky (Univerzita Komenského v Bratislave)

Description

Abstract
Benzene, toluene, and xylenes (BTX)[1] are common indoor air pollutants released from building materials, paints, adhesives, furnishings, and cleaning products. Long-term exposure to them is linked to serious health risks, and benzene is a recognized human carcinogen. Conventional BTX monitoring relies on sample collection and laboratory analysis by gas chromatography, which is slow, costly, and poorly suited to routine on-site surveillance of buildings. Photoionization ion mobility spectrometry (PI-IMS) offers fast, sensitive, and portable detection of volatile organic compounds [2,4,5], and its performance depends on the ionization source [4] and its supporting electronics. This research will design and develop a direct-current (DC) discharge krypton vacuum ultraviolet (VUV) lamp emitting at 10.6 eV [3], together with the high-voltage electronics required to operate a PI-IMS system. The primary objectives are to produce a stable VUV source whose photon energy exceeds the ionization energies of BTX compounds (approximately 8.4 to 9.2 eV) but remains below those of the main air components, nitrogen, oxygen, and water vapor; develop a reliable DC high-voltage supply with current-limiting control for lamp ignition and stable discharge, along with a high-voltage supply for the drift-tube electric field; and implement a low-noise amplifier stage for measuring weak ion currents. The mechanical design is complete, all components have been cleaned, and the resistor network and amplifier have been installed. The next stages are to assemble the lamp and electronics into the drift tube, characterize lamp output, ignition behavior, and long-term stability, and test the system with BTX standard gases and indoor air in buildings. Performance will be evaluated through sensitivity, limit of detection, resolving power, response time, and repeatability. The expected outcome is a compact, low-cost, and reproducible ionization and electronics platform for PI-IMS, supporting portable analyzers for indoor air quality monitoring, early detection of BTX emission sources, and occupational health protection in buildings.

Keywords: photoionization ion mobility spectrometry, PI-IMS, krypton (Kr) VUV lamp, 10.6 eV, DC discharge, high-voltage electronics, BTX, indoor air quality, volatile organic compounds (VOC), drift tube

Reference
[1] Baumbach, J. I., Sielemann, S., Xie, Z., & Schmidt, H. (2003). Detection of the gasoline components methyl tert-butyl ether, benzene, toluene, and m-xylene using ion mobility spectrometers with a radioactive and UV ionization source. Analytical chemistry, 75(6), 1483-1490.
[2] Borsdorf, H., & Eiceman, G. A. (2006). Ion mobility spectrometry: principles and applications. Applied Spectroscopy Reviews, 41(4), 323-375.
[3] Cheng, S., Dou, J., Wang, W., Chen, C., Hua, L., Zhou, Q., ... & Li, H. (2013). Dopant-assisted negative photoionization ion mobility spectrometry for sensitive detection of explosives. Analytical chemistry, 85(1), 319-326.
[4] Chen, C., Jiang, D., & Li, H. (2019). UV photoionization ion mobility spectrometry: Fundamentals and applications. Analytica Chimica acta, 1077, 1-13.
[5] Cameras, R., Figueras, E., Davis, C. E., Baumbach, J. I., & Gracia, I. (2015). Review on ion mobility spectrometry. Part 1: current instrumentation. Analyst, 140(5), 1376-1390.
Acknowledgement
This research was funded by the Slovak Research and Development Agency (SRDA; Grant APVV-23-0522) and by the EU’s NextGenerationEU via Slovakia’s Recovery and Resilience Plan (Projects 09I03-03-V02-00036 and 09I01-03-V04-00025).

Pracovisko fakulty (katedra)/ Department of Faculty Katedra experimentálnej fyziky
Tlač postru/ Print poster Budem požadovať tlač /I hereby required to print the poster in faculty

Author

Mr Ashish Kumar (Katedra experimentálnej fyziky, Fakulta matematiky, fyziky a informatiky (Univerzita Komenského v Bratislave)

Co-authors

Dr Emanuel Maťaš (Katedra experimentálnej fyziky, Fakulta matematiky, fyziky a informatiky (Univerzita Komenského v Bratislave) Ladislav Moravský (Katedra experimentálnej fyziky, Fakulta matematiky, fyziky a informatiky (Univerzita Komenského v Bratislave) Priyanka Kumari (Katedra experimentálnej fyziky, Fakulta matematiky, fyziky a informatiky (Univerzita Komenského v Bratislave) Dr Vahideh Ilbeigi (Katedra experimentálnej fyziky, Fakulta matematiky, fyziky a informatiky (Univerzita Komenského v Bratislave) Prof. Štefan Matejčík (Katedra experimentálnej fyziky, Fakulta matematiky, fyziky a informatiky (Univerzita Komenského v Bratislave)

Presentation materials

There are no materials yet.